-40%

DTH1 Temperature Humidity High-precision Dual-output Automatic Controller Module

$ 8.26

  • Accuracy: 0.1℃/ 0.1%RH
  • Brand: Unbranded
  • Chip: SHT30
  • Country/Region of Manufacture: China
  • EAN: Does not apply
  • Humidity Range: 00%-100%RH
  • Marke: Markenlos
  • Model: XY-DTH1
  • Output Type: Relay output
  • Temperature measurement range: -20℃-60℃
  • Type: Thermostat
  • UPC: Does not apply
  • gtin13: Does not apply

Description

Visit store Items for sale About us Product Details precision digital display word double output automatic constant temperature and humidity control panel Product adopts industrial-grade chip, high-precision SHT30 temperature and humidity sensor. Product Function: Product features are two main types of classification: the functions of temperature and humidity; Function of temperature are as follows: The automatic identification of work mode: The system automatically according to the start/stop temperature, identify work mode; Start temperature > stop temperature, cooling mode 'C'. Start temperature < stop temperature, heating mode 'H'. Cooling mode: When the temperature ≥ Start temperature, relay conduction, red led on, refrigeration equipment begin to work; When the temperature ≤ Stop temperature, relay disconnect, red led off, refrigeration equipment stop to work; Heating mode: When the temperature ≤ Start temperature, relay conduction, red led on, heating equipment begin to work; When the temperature ≥ Stop temperature, relay disconnect, red led off, heating equipment stop to work; Temperature correction function OFE (-10.0 ~ 10℃): The system is working for a long time and may be biased, through this function correction, the actual temperature = measuring temperature + calibration value; How to set the start/stop temperature: In the running interface, Long Press ' TM+ ' key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM- key, to be modified, waiting for 6s automatic exit and save; In the running interface, Long Press ' TM-' key more than 3 seconds, into the stop temperature settings interface, can be modified by TM+ TM- key, to be modified after the parameters, waiting for 6s automatic exit and save; The humidity function is as follows: The automatic identification of work mode: The system automatically according to the start/stop humidity, identify work mode; Start humidity> stop humidity, dehumidification mode 'D'. Start humidity< stop humidity, humidification mode 'E'. Dehumidification mode: When the humidity≥ Start humidity, relay conduction, green led on, dehumidification equipment begin to work; When the humidity≤ Stop humidity, relay disconnect, green led off, dehumidification equipment stop to work; Humidification mode: When the humidity≤ Start humidity, relay conduction, green led on, humidification equipment begin to work; When the humidity≥ Stop humidity, relay disconnect, green led off, humidification equipment stop to work; Humidification correction function RH (-10.0 ~ 10%): The system is working for a long time and may be biased, through this function correction, the actual humidity = measuring humidity + calibration value; How to set the start/stop humidity: In the running interface, Long Press ' RH+ ' key more than 3 seconds, into the start humidity settings interface, can be modified by RH + RH - key, to be modified, waiting for 6s automatic exit and save; In the running interface, Long Press ' RH-' key more than 3 seconds, into the stop humidity settings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save; Running Interface Description: Working mode shows that the current mode ("H/C", "E/d") will be synchronized at the front of temperature/humidity, when the setting of temperature/humidity and stop temperature/humidity are completed. Any relay conduction, the upper-left corner of the interface display "out", if the temperature relay conduction, the flashing display temperature working mode "H/C" to show reminders; if the humidity relay conduction, then flashing display humidity working mode "E/d", as a reminder; Other features: Relay enabling (by default): If the relay is disable, the relay remains disconnected; How to modify the temperature/humidity correction value: In the operating interface, double-click the ' TM+ ' key to enter the correction of the set interface, the downward display correction of the type, the upward display of specific values; (OFE: Temperature correction value RH: Humidity correction value) At this time by a short press ' TM-' key, switch to modify the parameters, through the RH+ RH-key, modify the specific value of the support long press short; When the parameters have been modified, double-click the ' TM+ ' key, exit the correction positive setting interface, and save the data; How to enable/disable relay: In the running interface, Short press ' TM-' key, enable/disable the temperature relay(ON: enable OFF: disable), back to the running interface, if the temperature relay is disable, the temperature symbol ' ℃ ' flashes to remind. In the running interface, Short press ' RH-' key, enable/disable the humidity relay (ON: enable OFF: disable), back to the running interface, if the humidity relay is disable, the humidity symbol '% ' flashes, as a reminder. Payment Method Shipping Policy Returns & Refund Policy Feedback Payment Method EBAY Managed Payment. But we only Accept your Ebay Address , please Make sure it's 100% right. Payment must be received in 5 business days of auction closing. Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order. Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched. Shipping Policy 1. We only ship to the confirmed address provided by eBay. please make sure your ebay address is 100% matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand. 2. Orders will be processed instantly and dispatched within 1-3 business days except hoilday, so we do NOT accept any email/message note after you place orders. 3. All package need to wait 30 days,Please take care it.Less than 30 days,we can't take a refund. Returns & Refund Policy All package need to wait 30 days (US only n eed 7-10 days) , Please take care it.Less than 30 days,we can't take a refund . If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please keep in touch with us and double check the return address before you return it. If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item. Feedback We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very important to us. We request that you keep in touch with us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns.